Артикул: CDF-210P

Все товары PARKER

CDF® Fuel Monitor Cartridges CDF-210P

Доступно к заказу

Цена по запросу

Гарантия лучше цены
Предложим наиболее выгодную цену на данный товар

Parker Velcon EI1581 CDF® Fuel Monitor cartridges for removal of water, filtering of solids and reduction of static charge in aviation fuel.

CDF® Fuel Monitor Cartridges

EI 1583 6th Edition P Series
Field Proven: CDF® Replacement Cartridges Assure Clean Dry Fuel Delivery

Description

The Velcon CDF® P Series cartridges are designed to provide superior performance and reliability in standard fuel monitor housings through a unique, patented combination of media that absorbs water, filters solids that may be present in the fuel and provides for reduced static charge.

The cartridge has injection molded endcaps that are bonded to the media and an O-ring seal on the outlet end. This minimizes the possibility of bypassing contaminated fuel or transmission of water downstream at low flow rates.
As the cartridge removes water and/or dirt from the influent fuel there will be an increase in the pressure differential along with a decrease in flow rate. These changes are the result of flow restriction caused by dirt retention or water absorption in the media. The rate of these changes depends on the quantity of water or dirt contamination in the fuel.

Features

- CDF® P SERIES are qualified to EI 1583 Sixth Edition specification for Aviation Fuel Filter Monitors.
- IMPROVED SALT WATER PERFORMANCE
- CONDUCTIVE END CAPS and adhesive to reduce static charge within the vessel.
- O-RING SEAL minimizes the possibility of bypassing contaminated fuel at differential pressures up to 175 psi.
- RUGGED CONSTRUCTION collapse strength exceeds 175 psi differential pressure.

The Velcon CDF® P Series cartridges are designed to provide superior performance and reliability in standard fuel monitor housings through a unique, patented combination of media that absorbs water, filters solids that may be present in the fuel and provides for reduced static charge.

The cartridge has injection molded endcaps that are bonded to the media and an O-ring seal on the outlet end. This minimizes the possibility of bypassing contaminated fuel or transmission of water downstream at low flow rates.

As the cartridge removes water and/or dirt from the influent fuel there will be an increase in the pressure differential along with a decrease in flow rate. These changes are the result of flow restriction caused by dirt retention or water absorption in the media. The rate of these changes depends on the quantity of water or dirt contamination in the fuel.

EI Specification 1583 6th Edition Information

Velcon's new CDF®-P Series Cartridges incorporate several structural features due to requirements of the Sixth Edition of EI 1583. Some of these include:

- Increased product conductivity to decrease the risk of electrostatic discharges
- Improved media structure to lower the risk of media migration
- Lower initial DP - a major factor for installations that require changing cartridges at 15 PSID.
- New structure that provides longer cartridge life in the presence of small amounts of water

Some of the new requirements of the sixth edition of EI 1583 are:
- 18 lab qualification tests vs. 14 for the 4th edition
- Testing salt resistance
- Testing for cartridge conductivity
- Testing for structural integrity
- Testing for any trace SAP migration
- Water slug test at low flow (10% of rated flow)
- Low water (50 ppmv) at low flow (10% of rated flow)

SPECIFICATIONS AND TECHNICAL INFORMATION CDF® P SERIES

- 175 psid (12 bar) collapse strength
- 0.5 micron rating
- 160°F maximum operating temp.
- Recommended changeout differential pressure = 25 psid
- Typical water holding capacity for CDF-230P is 120 ml.
- For service life information, please refer to Operating Procedures # VEL1839 or consult your company fuel handling procedures.


Характеристики

Номинальное значение в микронах (мкм):0.5
Сертификаты:EI1583
Применение:Aviation
Наружный диаметр (дюймы):20
Длина (дюймы):10.8125
Тип фильтра:Aviation Fuel Monitor
Давление смятия:175 psi
Максимальная рабочая температура:71.1 °C, 160 °F
Расход:10 Gal/min
Разность давлений при замене:25 psi, 1.72 bar
Бренд:Velcon
Применение:Aviation
Характеристики
Бренд
Velcon
Давление смятия
175 psi
Длина (дюймы)
10.8125
Максимальная рабочая температура
71.1 °C, 160 °F
Наружный диаметр (дюймы)
20
Номинальное значение в микронах (мкм)
0.5
Применение
Aviation
Разность давлений при замене
25 psi, 1.72 bar
Расход
10 Gal/min
Сертификаты
EI1583
Тип фильтра
Aviation Fuel Monitor

Мы предлагаем следующие способы доставки товара:

Самовывоз из пункта выдачи

Самостоятельное получение заказа в пункте выдачи. Дата и время получения заранее согласуется с менеджером магазина.
Отгрузка товара юридическим лицам осуществляется только при наличии печати или правильно оформленной и заполненной доверенности, наличии паспорта получателя.


Курьерская доставка по Москве

Доставка по адресу покупателя или до пункта приема транспортной компании в г. Москве. Дата и время доставки заранее согласуется с менеджером магазина.

Доставка транспортной компанией по России

Доставка транспортной компанией по России до пункта выдачи транспортной компании или до конечного адреса покупателя. 
 

Отзывы0

Нет отзывов об этом товаре.

Написать отзыв

Рейтинг

Отзывы с оценкой
0% 0 отзывов
0% 0 отзывов
0% 0 отзывов
0% 0 отзывов
0% 0 отзывов